Function & features:
1. Three kinds of mode: Rate Mode, Time Mode, Body Weight Mode.
2. User-friendly, easy to operate, safe and convenient. English indicators, easy to identify.
3. Accept all standard syringes of 5ml, 10ml, 20ml, 30ml and 50ml. It will self-diagnose and display the syringes size and set parameter automatically in the form of menu.
4. Unique injection supervision system ensures the safe injection and reduces the nurse`s workload.
5. Excellent injection operation. The accuracy will be ensured even at small-volume injection.
6. Double CPU system makes the process of injection safer and more reliable.
7. Precision step motor. There is no pulsating wave even during low-rate injection.
8. Accurate and sensitive pressure sensor detects occlusion pressure accuracy.
9. Alarm is given when there is malfunction or operation error, and the machine stops running automatically.
10. KVO rate can be selectable according to concrete requirements from 0.1ml/h to 5ml/h.
11. Save the preset volume automatically when there is unpredictable switch off, ensuring the accuracy of injection volume.
12. Injection time, dose, solution can be checked during the process of injection.
Technical Parameter:
|
Dimension
|
288?30??xml:namespace prefix = st1 ns = "urn:schemas-microsoft-com:office:smarttags" />122mm
|
|
Weight
|
<3.0kg
|
|
|
Power supply
|
50/60Hz AC100V~240V
|
Battery
|
Rechargeable lithium polymer battery, 7.4V, 1600mA
|
|
|
Occlusion value
|
400mmHg~900mmHg
|
Injection increment
|
0.1ml
|
|
|
Displayed information
|
Rate, Σ, Volume limit, Syringe size, Pressure value, Battery capacity, Unit of medical dosage, AC power indicator, Bed No., Pressure Value
|
Feasible syringe
rate range
|
5ml : 0.1~100ml/h 10ml : 0.1~200ml/h
20ml : 0.1~400ml/h 30ml : 0.1~600ml/h
50ml : 0.1~1500ml/h
|
|
|
Fuse
|
220V2A?, 12V2A?
|
KVO rate
|
0.1ml/h~5.0ml/h(selectable)
|
|
|
Maximum power consumption
|
25VA, 5h after being recharged
|
Bolus rate
|
5ml: 100ml/h 10ml: 200ml/h 20ml: 400ml/h
30ml: 600ml/h 50ml: 1500ml/h
|
|
|
Accumulated injection volume
|
0~9999.9ml
|
Selectable mode
|
Rate mode, Time mode, Body weight mode
|
|
|
Injection accuracy
|
±2%
|
Time Mode
|
Volume limit: 0.1~999.9ml Time: 0~2000seconds
|
|
|
Alarm function
|
OVER, NEAR, Occlusion, Low battery, Syringe disengaged, Syringe abnormal, Control abnormal, Internal malfunction
|
Body Weight Mode
|
Selectable unit: ml/h, mg/h, ug/h, mg/kg/h, mg/kg/min, ug/kg/h, ug/kg/min
|
|
|
Drug limit: 0.1~9999.9(mg/ug), Solution limit: 0.1~999.9ml, Weight: 01~300.0kg, Dose: 0.1~9999.9
|
|
|
Electromagnetic compatibility
|
Comply with the stipilation of IEC60601-1-2(1993 edition )EN60601-1-2-24
|
|
|
Electrical safety
|
Comply with the stipulation of GB9706.1-1995, EN60601-1 and UL60601-1
|
operating conditions
|
Environment temperature 5~45°C, air pressure 70~106kPa, relative humidity 30%~90%
|
|
|
Applicable syringes
|
All brands of standard Syringes: 5ml,10ml,20ml,30ml,50ml
|
Storage
|